Compliance

What is checked, and how often

General information about the checks a building usually carries, the frequency they are usually done at, who usually does them and what evidence is kept afterwards.

Your building's regime and the regulations apply.

This page is a description of common practice, not a statement of law and not advice. It names no regulation and states no legal requirement, because the regime that applies to your building depends on the building, its use, its systems and its risk assessment. What Aintrees holds is the frequency agreed with you, and the report shows whether it was met.

Fire alarm and call pointsWhat is checkedPanel healthy and free of faults, one call point tested in rotation, sounders heard across the building.Typical frequencyWeekly test · service typically annuallyWho typically does itIn-house on the weekly round; certified contractor for the serviceEvidence keptLogbook entry naming the call point tested, and the contractor's service certificate.
Emergency lightingWhat is checkedFunction test of each luminaire, and a full-duration discharge test of the installation.Typical frequencyMonthly function · duration test typically annuallyWho typically does itIn-house on the round; contractor where the duration test is contracted outEvidence keptTest record per luminaire with failures raised as faults, and the duration test report.
Fire extinguishersWhat is checkedIn place and unobstructed, seal intact, gauge in range, signage present and legible.Typical frequencyMonthly visual · service typically annuallyWho typically does itIn-house visual; certified contractor for the serviceEvidence keptRound sheet, and the service label and certificate held against each unit.
Hot and cold water outletsWhat is checkedTemperature at sentinel outlets after the stated run time, against the thresholds set for the building.Typical frequencyMonthly temperatures · weekly flush for little-used outletsWho typically does itIn-house on the round; specialist contractor for tank and system workEvidence keptReading with date, outlet reference and the threshold used, and a fault where a reading fails.
Fire doorsWhat is checkedCloses onto the latch from any angle, seals and strips intact, gaps within the set tolerance, signage present.Typical frequencyTypically quarterly, more often on high-traffic doorsWho typically does itIn-house on a recorded check; joiner or contractor for repairEvidence keptCheck sheet per door with the defect noted, and the repair tracked as a fault.
LiftsWhat is checkedAlarm answered and doors operating in-house; thorough examination by a competent person.Typical frequencyWeekly alarm and door check · thorough examination typically six-monthlyWho typically does itIn-house weekly; competent person appointed for the examinationEvidence keptRound sheet for the weekly check, and the report of the thorough examination.
Gas appliances and boilersWhat is checkedService and safety check of the appliance, flue and controls by a registered engineer.Typical frequencyTypically annually, or to the manufacturer's intervalWho typically does itRegistered contractor, arranged and evidenced by usEvidence keptThe engineer's certificate, filed against the asset on the register.
Electrical installationWhat is checkedVisual condition of boards, accessories and flexible leads in-house; periodic inspection and testing by a competent person.Typical frequencyAnnual visual · condition report typically five-yearlyWho typically does itIn-house visual; competent contractor for the inspection and testingEvidence keptRound sheet for the visual, and the installation condition report with its observations.

Your building's regime and the regulations apply.

Compliance

What we arrange rather than carry out

Gas servicing, lift examinations, electrical inspection and testing and similar work are carried out by certified or competent third parties. We book them, attend where access is needed, check that the certificate matches the asset, and file it against the register so that it can be found a year later without a search.

Accreditations

None are named on this site. Aintrees does not print an accreditation logo, a scheme number or a membership until the certificate is in hand and current, so this section stays empty rather than decorative. Ask with any enquiry and the current certificates will be sent with the quote.

Compliance

What is checked, and how often

Your building's regime and the regulations apply.